Introduction

The BCM2-300 series is a fully automatic live cell imaging system, with bright field, phase contrast and 3-channel fluorescent observation. It abandons the bulky housing and complicated operating steps of ordinary biological microscopes, allowing cell observation in one step. The built-in high-speed and high-sensitivity camera has a time-lapse shooting function, which can fully record the cell culture process.

Details

Model:BCM2-300
Bright Field Observation:Transmitted phase contrast illumination
Objective:Select any two from 4X/10X/20X objectives
Stage:Motorized X/Y moving stage
Focusing System:Motorized
Camera:5MP, 2/3”, 40fps
Share

Overview

Packaging & Delivery

Packaging Details:Strong Carton with Polyfoam Protection

Port:Beijing

Lead Time:Within 2-4 Weeks after Receiving Payment

Introduction

The BCM2-300 series is a fully automatic live cell imaging system, with bright field, phase contrast and 3-channel fluorescent observation. It abandons the bulky housing and complicated operating steps of ordinary biological microscopes, allowing cell observation in one step. The built-in high-speed and high-sensitivity camera has a time-lapse shooting function, which can fully record the cell culture process.

Features

1. Bright field/ phase contrast

One-key switch between bright field and phase contrast for observing different samples.BCM2-300 Bright Field Phase Contrast

 

2. 3-channel fluorescence

Standard with 3 color excitation band fluorescence, B/G/U, motorized one-key switch.

BCM2-300 channel Fluorescence

 

3. Sealed, waterproof and corrosion resistant

Sterilizable via alcohol, double-distilled water/pyrroloquinoline, UV.

Usable in CO2 incubators.

Sealed, Waterproof and Corrosion Resistant

 

Sealed, Waterproof and Corrosion Resistant

 

4. Compatible with most common carriers

Compatible with multiple carriers, fitting various cell plates, dishes, flasks, slides and other containers, suitable for diverse experiments.

Compatible with Most Common Carriers

 

5. Low phototoxicity LED light source

625nm red LED bright field illumination, with low photobleaching and cytotoxicity, to protect samples and extend cell observation time.

Low Phototoxicity LED Light Source

 

6. Motorized dual objectives

Pre-set diaphragm with dual-objective configuration, optional magnifications of 4X/10X/20X objectives.

Motorized Dual Objectives

 

7. Motorized X/Y stage & Z-axis focus

Motorized stage with X/Y scanning and motorized Z-axis, with auto-intelligent focusing.

Motorized XY Stage & Z-Axis Focus

 

8. One-click whole well scan and stitching

Navigational scanning settings enable grouping, free-arm skipping of any regions, stitching of scans of adjacent fields of view and stitching of scans of the entire field of view.

One-click Whole Well Scan and Stitching

 

One-click Whole Well Scan and Stitching

 

9. Z-stack scan

High-precision motorized Z-axis: freely set Z-stack range/step for automatic scanning and layer imaging. Defocus removal algorithms enable clear imaging of thick samples, e.g., organoids.

Z-stack Scan

 

Z-stack Scan

 

10. Multi-channel scan & overlay

Navigational settings for multi-channel scanning, including multi-color fluorescence as well as bright field and phase contrast channels, enabling overlay output of images from any two or more channels.

Multi-Channel Scan & Overlay

 

Multi-Channel Scan & Overlay

 

11. Continuous time lapse acquisition

Long-term continuous shooting can generate time-lapse videos of any field of view and any duration, presenting complete information of the whole cycle of living cell samples.

Continuous Time Lapse Acquisition

 

Continuous Time Lapse Acquisition

 

12. Intelligent analysis functions

Comes with image recognition and AI deep learning modules. Matches optimal analysis algorithms for different cell experiments, expandable with advanced modules like organoid, nerve cell and tumor sphere analysis.

Intelligent Analysis Functions

 

13. Cell confluency

Cell confluency is the percentage of surface area covered by cells in 2D culture. Timed live-cell imaging and data analysis determine confluency, plotting confluency-over-time curves and cell-count curves per channel. It is widely used in cell passaging, transfection, virus infection, drug treatment, etc.

Cell Confluency

 

14. Scratch assay

The cell scratch assay evaluates adherent cell migration. Create a scratch on the dish to simulate a wound, imaging at preset time points and quantitatively measuring cell migration between two rows. It is used for researching cell proliferation, migration, wound healing and drug screening.

Scratch Assay

 

15. Fluorescence transfection efficiency

Transfected cells with fluorescent label are imaged at different time points post-transfection. Cell counting function counts and record cells per channel, used in gene research, drug development, CGT, stem cell and organoid studies, etc.

Fluorescence Transfection Efficiency

 

16. Cell viability

Bright field and fluorescence images are taken. Cell counting counts total and dead cells (fluorescent). Time-point data records generate a cell viability curve. It is used in cell toxicity, drug development, CGT, vaccine R&D and production.

Cell Viability

Application

1. Dynamic monitoring of organoids

As 3D culture models, organoids fill the gap between 2D cells and animal models, widely used in disease simulation, drug testing and regenerative medicine.

Kinetics of organoid formation

Quantitatively monitor the impact of seeding density on formation efficiency. Track the aggregation process and record the tensor of area/volume changes.

Migration ability assessment

Invasive analysis of tumor organoids.

Drug sensitivity testing

Real-time recording of the morphological collapse of organoids in response to chemotherapy drugs.

 

2. Drug development

Live-cell imaging replaces traditional endpoint methods, enabling dynamic quantification of drug effects and accelerating preclinical research.

Internalization and bystander effect of ADC drugs

Dual-color fluorescence tracking of the intracellular transport of antibody-drug conjugates.

Dynamic toxicity assessment of small molecules

Killing efficacy of immune cells

Recording the lysis process of tumor spheroids by NK cells.

 

3. Development of stem cell therapy products

The activity and differentiation stability of stem cells are the core of quality control for therapeutic agents and require non-destructive long-term monitoring.

Quality control of proliferation activity

Auto-confluency analysis of umbilical cord MSCs for harvest remainders.

Differentiation tendency early warning

Tracking early morphological changes in adipogenic/osteogenic differentiation.

Stability of cell therapeutic products

Verification of survival rate after cryopreservation and recovery.

 

4. Monitoring of cell industrial processes

Monitor cell culture conditions to evaluate culture status, experimental status, and subculture timing and control quality.

Batch-to-batch consistency management

Comparison of proliferation curves of CHO cells from different batches.

Real-time contamination early warning

AI-based morphological recognition of bacterial/fungal contamination.

Stability of cell therapy products

Monitoring of aggregation behavior during CAR-T cell expansion.

 

5. Agricultural science

Plant-pathogen interaction research, fertility and organelle localization of beans, gene function and protein expression research, etc.

 

6. Cell industry

Cell culture experiment monitoring, in-line quality control of bioreactors, stability monitoring of cell therapy products, etc.

 

7. Immunology

Macrophage phagocytosis tracking, neutrophil activation analysis, collagen-induced immune monitor, etc.

 

8. Neuroscience

Neuron network formation and construction, research on neural stem cell differentiation, quantitative analysis of brain organoids, etc.

 

9. Drug R&D

Preliminary toxicity screening of chemical drugs, early activity evaluation of compounds, research on drug action mechanisms, etc.

 

10. Regenerative medicine

Skin wound healing model, basic research on adipogenesis, monitoring of adhesion behavior of tissue engineering scaffolds, etc.

 

11. Stem cell applications

Pluripotency detection of stem cells, early warning of directed differentiation, dynamic monitoring of organoid morphology, etc.

 

12. Tumor research

Detection of apoptosis and necrosis, analysis of tumor cell migration and invasion, evaluation of chemotherapeutic drug activity, etc.

 

13. Aquaculture

Fish health assessment and germplasm optimization, fish immune invasion early warning, reproductive cell viability analysis, etc.

Specification

Item

Specification

Bright Field Observation

Transmitted phase contrast illumination, working distance 55mm

50,000 hours long lifespan, 625nm low-phototoxicity LED light source

Fluorescence Observation

(Fluorescence Wavelengths Customizable)

Blue (B): 472-495nm

Green (G): 543-560nm

Ultraviolet (UV): 393-416nm

Objective

Select any two from 4X/10X/20X objectives

Motorized objective switching

Stage

Motorized X/Y moving stage, moving range: 115mm*77mm, repeatability accuracy ≤3μm

Focusing System

Motorized, auto-focus mechanism

Camera

High-speed and high-sensitivity camera, 5MP, 2/3”, 40fps

Software

Supporting remote control, including illumination control, camera control, photo taking, video recording, time-lapse photography

Analysis Function

Cell counting, cell confluency, scratch assay, transfection efficiency, viability analysis

Scanning Function

Multi-well imaging: custom-set X/Y array for multi-point photography, bright field and fluorescence multi-channel overlay

Region scanning: set rectangular regions for full-scan stitching, bright field and fluorescence multi-channel overlay

Data transmission

/ Power Supply

USB data cable, DC power Cable

Working Environment

5-40°C, 20-95% RH

Dimensions

252mm*377mm*208mm

Package Dimension

& Weight

55cm*43cm*35cm, 14.1kg

Dimension

BCM2-300 Dimension

Unit: mm

Leave A Message