PRODUCTS
Home - Products - BUC6B-280C TE-Cooling C-mount USB3.0 CCD Camera(ICX674AQG Sensor)
BUC6B-280C TE-Cooling C-mount USB3.0 CCD Camera(ICX674AQG Sensor)
BUC6B-280C TE-Cooling C-mount USB3.0 CCD Camera(ICX674AQG Sensor)
BUC6B-280C TE-Cooling C-mount USB3.0 CCD Camera(ICX674AQG Sensor)
BUC6B-280C TE-Cooling C-mount USB3.0 CCD Camera(ICX674AQG Sensor)
BUC6B-280C TE-Cooling C-mount USB3.0 CCD Camera(ICX674AQG Sensor)
BUC6B-280C TE-Cooling C-mount USB3.0 CCD Camera(ICX674AQG Sensor)
BUC6B-280C TE-Cooling C-mount USB3.0 CCD Camera(ICX674AQG Sensor)
BUC6B-280C TE-Cooling C-mount USB3.0 CCD Camera(ICX674AQG Sensor)
BUC6B-280C TE-Cooling C-mount USB3.0 CCD Camera(ICX674AQG Sensor)
BUC6B-280C TE-Cooling C-mount USB3.0 CCD Camera(ICX674AQG Sensor)

BUC6B-280C TE-Cooling C-mount USB3.0 CCD Camera(ICX674AQG Sensor)

Introduction

BUC6B-280C(With ICX674AQG(C) Sensor) cameras adopt Sony Exview HAD CCD II sensor as the image capture device with two-stage peltier cooling sensor chip to -40 degree below ambient temperature.

Details

Model:BUC6B-280C
Sensor & Size(mm):2.8M/ICX674AQG(C) 2/3“ (8.81x6.63)
Pixel(μm):4.54x4.54
FPS/Resolution15@1938x1460,17@1610x1212,18@1930x1092
Binning:1x1
Exposure:0.07ms~1h
Spectral Range:380-650nm
USB Port:USB2.0 High-speed Port
Share

Overview

Quick Details

Model:BUC6B-280C

Sensor & Size(mm):2.8M/ICX674AQG(C) 2/3“ (8.81x6.63)

Pixel(μm):4.54x4.54

FPS/Resolution15@1938x1460,17@1610x1212,18@1930x1092

Binning:1x1

Exposure:0.07ms~1h

Spectral Range:380-650nm

USB Port:USB2.0 High-speed Port

Packaging & Delivery

Packaging Details:Strong Carton with Polyfoam Protection

Port:Beijing

Lead Time:Within 1-2 weeks after receiving payment

Introduction

BUC6B-280C(With ICX674AQG(C) Sensor) cameras adopt Sony Exview HAD CCD II sensor as the image capture device with two-stage peltier cooling sensor chip to -40 degree below ambient temperature.

The cooling temperature can be controlled by software to ensure that the photoelectric conversion quantum efficiency is as high as possible. This will greatly increase the signal to noise ratio and decrease the image noise. Smart structure is designed to assure the heat radiation efficiency and avoid the moisture problem. Electric fan is used to increase the heat radiation speed.

USB3.0 is used as the data transfer interface to increase the frame rate.

BUC6B series cameras come with advanced video & image processing application ImageView; Providing Windows/Linux/OSX multiple platform SDK; Native C/C++, C#/VB.NET, DirectShow, Twain Control API.

The BUC6B can be widely used in low light environment and microscope fluorescence image capture and analysis, as well as the astronomy deep sky application.

Features

The basic characteristic of BUC6B can be summarized as follows:

  1. Standard C-Mount camera with SONY ExView HAD CCD II sensors from1.4M to 12M;
  2. Two-stage TE-cooling with controllable electric fan;
  3. Sensor chip cooling up to 40°C below ambient temperature;
  4. Working temperature can be regulated to specified temperature in 5 minutes;
  5. Smart structure to assure the heat radiation efficiency and avoid the moisture problem;
  6. IR-CUT/ARcoated windows;
  7. Up to 1 hour long time exposure;
  8. USB3.0 5Gbit/second interface ensuring high speed data transmission;
  9. Ultra-FineTMcolor engine with perfect color reproduction capability;
  10. With advanced video & image processing application ImageView;
  11. Support both video and trigger modes;
  12. Providing Windows/Linux/Mac OS multiple platforms SDK;
  13. Native C/C++, C#/VB.NET, DirectShow, Twain control API.

Application

The BUC6B series USB3.0 cooled CCD digital cameras can be widely used in low light environment and microscope fluorescence image capture and analysis, as well as the astronomy applications as following:

  1. Bright field microscope;
  2. Dark field, differential interference (DIC) microscope;
  3. live cell imaging, cell or histopathological examination, cytology;
  4. Defect analysis, semiconductor inspection, precision measurement;
  5. Weak light fluorescence imaging, GFP or RFP analysis, fluorescence in situ hybridization (FISH);
  6. Resonance fluorescence transfer microscope, total internal reflection fluorescence microscope, real – time confocal microscopy, failure analysis, astronomy photography.

Specification

Order Code

Sensor & Size(mm)

Pixel(μm)

G Sensitivity

Dark Signal

FPS/Resolution

Binning

Exposure

BUC6B-1200C

12M/ICX834AQG(C)
1“ (13.15×8.77)

3.1×3.1

420mv with 1/30s

15.2mv with 1/30s

3.6@4248×2836
3.6@2124×1418

1×1,

2×2

0.06ms~1h

BUC6B-1200M

12M/ICX834ALG(M)
1“ (13.15×8.77)

3.1×3.1

420mv with 1/30s

12mv with 1/30s

(F8.0)

3.6@4248×2836
3.6@2124×1418

1×1,

2×2

0.06ms~1h

BUC6B-900C

9.0M/ICX814AQG(C)
1“ (12.47×9.98)

3.69×3.69

580mv with 1/30s

12mv with 1/30s

4.4@3388×2712
4.4@1694×1356

1×1,

2×2

0.06ms~1h

BUC6B-900M

9.0M/ICX814ALG(M)
1“ (12.47×9.98)

3.69×3.69

660mv with 1/30s

12mv with 1/30s

(F8.0)

4.4@3388×2712
4.4@1694×1356

1×1,

2×2

0.06ms~1h

BUC6B-600C

6.0M/ICX694AQG(C)
1“ (12.48×9.99)

4.54×4.54

880mv with 1/30s

8mv with 1/30s

7.5@2748×2200
14@2748×1092

1×1

0.06ms~1h

BUC6B-600M

6.0M/ICX694ALG(M)
1“ (12.48×9.99)

4.54×4.54

1000mv with 1/30s

8mv with 1/30s

7.5@2748×2200
14@2748×1092

1×1

0.06ms~1h

BUC6B-280C

2.8M/ICX674AQG(C)
2/3“ (8.81×6.63)

4.54×4.54

800mv with 1/30s
4mv with 1/30s

15@1938×1460
17@1610×1212
18@1930×1092

1×1

0.05ms~1h

BUC6B-280M

2.8M/ICX674ALG(M)
2/3“ (8.81×6.63)

4.54×4.54

950mv with 1/30s
4mv with 1/30s

15@1938×1460
17@1610×1212
18@1930×1092

1×1

0.05ms~1h

BUC6B-140C

1.4M/ICX285AQ(C)
2/3“ (8.88×6.70)

6.45×6.45

1240mv with 1/30s
10mv with 1/30s

15@1360×1024

1×1

0.07ms~1h

BUC6B-140M

1.4M/ICX285AL(M)
2/3“ (8.88×6.70)

6.45×6.45

1300mv with 1/30s

11mv with 1/30s

15@1360×1024

1×1

0.07ms~1h

BUC6B-140BC

1.4M/ICX825AQA(C)
2/3“ (8.88×6.70)

6.45×6.45

2000mv with 1/30s
4.8mv with 1/30s

25@1376×1040

1×1

0.07ms~1h

BUC6B-140BM

1.4M/ICX825ALA(M)
2/3“ (8.88×6.70)

6.45×6.45

2000mv with 1/30s

4.8mv with 1/30s

25@1376×1040

1×1

0.07ms~1h

C:Color; M:Monochrome.

 

Other Specification for BUC6B Cameras

Spectral Range

380-650nm (with IR-cut Filter)

White Balance

ROI White Balance/ Manual Temp Tint Adjustment/NA for Monochromatic Sensor

Color Technique

Ultra-FineTM Color Engine/NA for Monochromatic Sensor

Capture/Control API

Native C/C++, C#/VB.NET, DirectShow, Twain and Labview

Recording System

Still Picture and Movie

Cooling System

Two-stage TE-cooling System -45 °C below Camera Body Temperature

Operating Environment

Operating Temperature (in Centigrade)

-10~ 50

Storage Temperature (in Centigrade)

-20~ 60

Operating Humidity

30~80%RH

Storage Humidity

10~60%RH

Power Supply

DC 5V over PC USB Port

External Power Adapter for Cooling System, DC12V, 3A

Software Environment

Operating System

Microsoft® Windows® XP / Vista / 7 / 8 /10 (32 & 64 bit)

OSx(Mac OS X)

Linux

PC Requirements

CPU: Equal to Intel Core2 2.8GHz or Higher

Memory:2GB or More

USB Port:USB2.0 High-speed Port

Display:17” or Larger

CD-ROM

Dimension of BUC6B

The BUC6B body, made from tough, alloy with CNC technique, ensures a heavy duty, workhorse solution. The camera is designed with a high quality IR-CUT or AR to block the IR light or protect the camera sensor. The fan‘s vibration is minimized to the low level to eliminate the vibration caused imaging blur. These measures ensure a rugged, robust solution with an increased lifespan when compared to other industrial camera solutions.

Packing Information for BUC6B

Standard Package

A

Carton L:50cm W:30cm H:30cm (20pcs, 12~17Kg/ carton), not shown in the photo

B

3-A safety equipment case: L:28cm W:23cm H:15cm (1pcs, 2.8Kg/ box); Carton size:L:28.2cm W:25.2cm H:16.7cm

C

BUC6B camera(C-mount)

D

Power adapter: input: AC 100~240V 50Hz/60Hz, ouut: DC12 V 3A

E

High-Speed USB3.0 A male to B male gold-plated connectors cable /2.0m

F

CD (Driver & utilities software, Ø12cm)

Optional Accessory

G

Adjustable lens adapter

C-mount to Dia.23.2mm eyepiece tube
(Please choose 1 of them for your microscope)

C-Mount to Dia.31.75mm eyepiece tube
(Please choose 1 of them for your telescope)

H

Fixed lens Adapter

C-mount to Dia.23.2mm eyepiece tube
(Please choose 1 of them for your microscope)

C-mount to Dia.31.75mm eyepiece tube
(Please choose 1 of them for your telescope)

Note: For F and G optional items, please specify your camera type(C-mount, microscope camera or telescope camera),  engineer will help you to determine the right microscope or telescope camera adapter for your application.

I

108015(Dia.23.2mm to 30.0mm Ring)/Adapter rings for 30mm eyepiece tube

J

108016(Dia.23.2mm to 30.5mm Ring)/ Adapter rings for 30.5mm eyepiece tube

K

External trigger control line

L

Calibration kit

106011/TS-M1(X=0.01mm/100Div.);
106012/TS-M2(X,Y=0.01mm/100Div.);
106013/TS-M7(X=0.01mm/100Div., 0.10mm/100Div.)